AOR-8, AOR-16, AOR-24, AOR-32 Rev 2 Flickering trouble lights, issue stays with location wiring
Ideal solution is to used shielded wire to prevent interference.
Alternate solution, add 47k ohm resistor across red and green (ring and tip) at the Call station end.
Can add up to 2 47k resistors in parallel.
Related Articles
AOR-5 or AOR-10 No power or battery light on front cover, but some trouble lights are lit for stations, and there are red LEDs lit on the PCB
The ribbon cable from the front panel to the PCB, is upside down when where it connects to the PCB. The red wire is pin 1 and should be at the top of the connector when it is correctly plugged into the PCB. Other symptoms include: Configure button ...
AOR-IP Command Unit Installation
This document covers the physical installation of the following AOR-IP Command Unit models: AOR-IP-40-CU AOR-IP-80-CU AOR-IP-120-CU AOR-IP-160-CU Fasteners The AOR-IP Command units can be surface mounted or flush mounted, as the particular ...
AOR-8/16/24/32 REV 2 with AOR-CSE stations trouble light flickers irregularly.
Add a 47k ohm resistor across the red and green wires at each of the AOR-CSE, or using shielded wire may help to alleviate the interference.
AOR-IP Operating Instructions
AOR-IP Series Command Unit Operating Instructions Master Telephone and Extension Button Panels Station Buttons/Status Indicators Green LED light on an individual station button, indicates that that station is registered to the system, and not ...
AOR-IP Command Unit (CU) Configuration
This document covers the basic configuration needed for any of the AOR-IP Command units. (AOR-IP-40-CU, AOR-IP-80-CU, AOR-IP-120-CU, AOR-IP-160-CU) General Information The AOR-IP command units ship pre-configured for up to 160 call station, one ...