AOR-8/16/24/32 REV 2 with AOR-CSE stations trouble light flickers irregularly.
Add a 47k ohm resistor across the red and green wires at each of the AOR-CSE, or using shielded wire may help to alleviate the interference.
Related Articles
AOR-5 or AOR-10 No power or battery light on front cover, but some trouble lights are lit for stations, and there are red LEDs lit on the PCB
The ribbon cable from the front panel to the PCB, is upside down when where it connects to the PCB. The red wire is pin 1 and should be at the top of the connector when it is correctly plugged into the PCB. Other symptoms include: Configure button ...
AOR-IP-CSE Revision 1 Call station Configuration
This article assumes that the suggested default IP scheme for the AOR-IP series is being used. The IP scheme can be found here . This article is for the first version of the AOR-IP-CSE That is based on the PCB with P/N 68820, It has two network ports ...
How to Set Number of Stations Connected to an AOR-5 or AOR-10 Series Master Controller
Fault Detection Configuration for AOR-CSE Stations and PSTN Line: Carrying out this procedure on the controller board is required for proper open/short fault and PSTN/POTS telephone line fault detection on the system. In the lower-right of the ...
AOR-8, AOR-16, AOR-24, AOR-32 Rev 2 Flickering trouble lights, issue stays with location wiring
Ideal solution is to used shielded wire to prevent interference. Alternate solution, add 47k ohm resistor across red and green (ring and tip) at the Call station end. Can add up to 2 47k resistors in parallel.
AOR-IP Series Master Document
This document contains the links to other relevant documentation for the installation and configuration of the various components of the AOR-IP series AOR-IP Command Units (AOR-IP-40-CU, AOR-IP-80-CU, AOR-IP-120-CU, AOR-IP-160-CU) Installation AOR-IP ...