ETP-500E not hanging up on Grandstream HT-814, HT-818, and HT-812
The HT-814, does not have the Loop Current disconnect signaling, that the ETP-500 will recognize, enabled by default. This will need to be enabled and the Loop Current Disconnect duration set to 700 ms.
Related Articles
Quick programming for the ETP-520 Series call stations
NOTE: After each programming code, a single beep indicates the code has been accepted. A double-beep indicates an error—re-enter the code again. 1.1. Quick Programming Guide Programming the ETP-520 Series Call Station is relatively quick and easy. ...
ETP-CDMA-V Troubleshooting
Troubleshooting calls using ETP-400/ETP-500 series and ETP-CDMA-V Is the ETP-CDMA-V receiving power? There should be several lights on the front face of the unit, that has the RJ-11 connection if the device is receiving power. If the power has been ...
ETP-520 Programming Example for Autodial/Ringdown/PLAR Lines
NOTE: After each programming code, a single beep indicates the code has been accepted. A double-beep indicates an error—re-enter the code again. 1.2. Accessing Programming Mode The ETP-520 Series Call Station can be programmed from a standard ...
BASIC Programming of Analog (ETP) Call Stations
What is the BASIC programming codes for the analog (ETP) devices? Resolution: What you will need: Analog telephone or test-set to dial in access to the ETP device The BASIC of QUICK programming for analog ETP devices is as follows: Default ...
How to change the Primary phone number on an ETP-400, ETP-500, ETP-100, ETP-103, or ETP-110
You will need to know the number associated with the telephone line that the Talkaphone is connected to, and the number that the Talkaphone should call when the button is pressed. This also assume that there is not another device on the line that is ...