ETP-WM Series ADA Mounting Height Recommendations

ETP-WM Series ADA Mounting Height Recomendations

     I.        ADA Height Requirements

In order for a call station to comply with the Americans With Disabilities Act (ADA), all operable parts (i.e. pushbuttons and keypad) must be no higher than 48.00” above the finished floor from a forward reach or 54.00” above the finished floor from a side reach.  Please note that the measurements outlined in this document are based on a figure of 47.50” to ensure ADA compliance.

    II.        Key Dimensions for 1-Button Call Station Installed in Wall Mount

Wall Mount Series with

1-Button Call Station

A

(Floor to Bottom of Wall Mount)

B

(Floor to Top of Pushbutton)

C

(Floor to Top of Wall Mount)

ETP-WM Series

41.50 in.

47.50 in.

73.37 in.

ETP-WM/E Series

41.85 in.

47.50 in.

73.72 in.

ETP-WMS Series

41.33 in.

47.50 in.

73.20 in.

ETP-WMSE Series

41.85 in.

47.50 in.

73.72 in.

WEBS-WM Series

40.50 in.

47.50 in.

72.44 in.

  III.        Key Dimensions for 2-Button Call Station Installed in Wall Mount

Wall Mount Series with

2-Button Call Station

A

(Floor to Bottom of Wall Mount)

B

(Floor to Top of Secondary Pushbutton)

C

(Floor to Top of Wall Mount)

ETP-WM Series

38.32 in.

47.50 in.

70.19 in.

ETP-WM/E Series

38.67 in.

47.50 in.

70.54 in.

ETP-WMS Series

38.15 in.

47.50 in.

70.02 in.

ETP-WMSE Series

38.67 in.

47.50 in.

70.54 in.

WEBS-WM Series

37.32 in.

47.50 in.

69.26 in.

  IV.        Key Dimensions for 2-Button with Keypad Call Station Installed in Wall Mount

Wall Mount Series with 2-Button/Keypad Call Station

A

(Floor to Bottom of Wall Mount)

B

(Floor to Top of Keypad)

C

(Floor to Top of Wall Mount)

ETP-WM Series

35.19 in.

47.50 in.

67.06 in.

ETP-WM/E Series

35.54 in.

47.50 in.

67.41 in.

ETP-WMS Series

35.02 in.

47.50 in.

66.89 in.

ETP-WMSE Series

35.54 in.

47.50 in.

67.41 in.

WEBS-WM Series

34.19 in.

47.50 in.

66.13 in.