How to Factory Reset a VOIP-22X Series Call Station
Reset to Factory Default Settings with Activated DHCP
To reset:
- While pressing the button, power up the station by connecting to a PoE switch
- Hold the button until the station audio starts counting, and release the button on count 1
- Press and hold the button on count 5 and release on count 0
- If there is no 0 count, the procedure has failed and you have to start again
- Press the button, and the station will speak its IP address
Factory default values
- Station IP address: Determined by DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
- Username: admin
- Password: alphaadmin
Reset to Factory Default Settings with Static IP
To reset:
- While pressing the call button, power up the station by connecting to a PoE switch
- Hold the button until the station audio starts counting, and release the button on count 1
- Press and hold the button on count 3 and release on count 0
- If there is no 0 count, the procedure has failed and you have to start again
- Press the call button, and the station will speak its IP address
Factory default values
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin