   Power
The AOR-IP-SUP includes a 24vdc 0.5A wall plug power adapter that will need to be connected to a 120v power supply, backup power may be required as per local codes.
On the X600M TM , the black/white wire connects to V+ and the black wire connects to V- .
Communication
A single CAT5e, or better will be needed to provide communications for the AOR-IP-SUP . This will connect to the ENET 1 .
The included Expansion cable is used to connect the X600M TM with the X12S TM , via the Expansion ports.
There are eight normally open relays on the X12S TM , that will accept 30AWG-14AWG wire, that is rated for at least 75°C.
| 14-Pin Connector Pinout | |
|---|---|
| Terminal | Description | 
| 1NO | 
      Relay 1 NO 
       | 
| 
      2NO  
       | 
      Relay 2 NO 
       | 
| 
      3NO  
       | 
      Relay 3 NO 
       | 
| 
      4NO  
       | 
      Relay 4 NO 
       | 
| 
      1-4COM  
       | 
      Relay 1,2,3,4 COM 
       | 
| 
      1-4COM  
       | 
      Relay 1,2,3,4 COM 
       | 
| 
      1-4COM  
       | 
      Relay 1,2,3,4 COM 
       | 
| 
      5NO  
       | Relay 5 NO | 
| 
      6NO  
       | 
      Relay 6 NO 
       | 
| 
      7NO  
       | Relay 7 NO | 
| 
      8NO  
       | 
      Relay 8 NO 
       | 
| 
      5-8COM  
       | 
      Relay 5,6,7,8 COM 
       | 
| 
      5-8COM  
       | 
      Relay 5,6,7,8 COM 
       | 
| 
      5-8COM  
       | 
      Relay 5,6,7,8 COM 
       |