Power
The AOR-IP-SUP includes a 24vdc 0.5A wall plug power adapter that will need to be connected to a 120v power supply, backup power may be required as per local codes.
On the X600M TM , the black/white wire connects to V+ and the black wire connects to V- .
Communication
A single CAT5e, or better will be needed to provide communications for the AOR-IP-SUP . This will connect to the ENET 1 .
The included Expansion cable is used to connect the X600M TM with the X12S TM , via the Expansion ports.
There are eight normally open relays on the X12S TM , that will accept 30AWG-14AWG wire, that is rated for at least 75°C.
14-Pin Connector Pinout |
|
---|---|
Terminal |
Description |
1NO |
Relay 1 NO
|
2NO
|
Relay 2 NO
|
3NO
|
Relay 3 NO
|
4NO
|
Relay 4 NO
|
1-4COM
|
Relay 1,2,3,4 COM
|
1-4COM
|
Relay 1,2,3,4 COM
|
1-4COM
|
Relay 1,2,3,4 COM
|
5NO
|
Relay 5 NO |
6NO
|
Relay 6 NO
|
7NO
|
Relay 7 NO |
8NO
|
Relay 8 NO
|
5-8COM
|
Relay 5,6,7,8 COM
|
5-8COM
|
Relay 5,6,7,8 COM
|
5-8COM
|
Relay 5,6,7,8 COM
|