Programming the EC-8 or AOR series, and Analog stations for Local Only

Programming the EC-8 or AOR series, and Analog stations for Local Only

Programming for an EC-8 or AOR  
  1. Call into the unit or go off hook on the local phone, be sure and select the correct bank if working with an AOR-16, AOR-14, or AOR-32, and what for three tones.
  2. Enter *31** to access programming,  wait for a single beep in confirmation.
  3. Enter *37* for Local Mode,  wait for a single beep in confirmation.

Programming for ETP-100, ETP-110, ETP-400 and ETP-500 series devices  

NOTE: If the *78* command has previously been entered into a call station, it will often reject the first attempt  at Entering *4**,  simply enter it a second time and be sure you hear a single confirmation tone in response.

  1. Call into the station with *4X*, where X is the port number connected to the station you wish to program, and wait for the ID tone to complete.
  2. Enter *4** to access programming, wait for a single beep in confirmation.
  3. Enter *13*1234567* as the primary number to be dialed, wait for a single beep in confirmation.
  4. Enter *55* to set the unit to disconnect on 30 seconds of silence from the remote side.
  5. Enter *18*Number of Rings*,  This is the number of rings before the station hangs up and tries again.  This should be between 3 and 9.
  6. Enter *78* to enable two-way conversation on inbound calls.
  7. Enter # to disconnect.
  8. Hang up the handset, and then repeat  this section for next station.

If you need additional assistance, please email us at support@talkaphone.com or call 773-539-1100 and select Technical Support.
    • Related Articles

    • Configuration for DataRemote CDS-9070 and ETP-500 Series Analog Call Stations

      Configuration for DataRemote\MetTel CDS-9070 and ETP-500 Series Analog Call Stations Configuration Required on the DataRemote\MetTel CDS-9070 CPC: Enabled CPC Delay: 10 seconds CPC Duration: 1 second Programming the ETP-500 series device Call into ...
    • AOR-IP Command Unit Installation

      This document covers the physical installation of the following AOR-IP Command Unit models: AOR-IP-40-CU AOR-IP-80-CU AOR-IP-120-CU AOR-IP-160-CU Fasteners The AOR-IP Command units can be surface mounted or flush mounted, as the particular ...
    • How to Set Number of Stations Connected to an AOR-5 or AOR-10 Series Master Controller

      Fault Detection Configuration for AOR-CSE Stations and PSTN Line: Carrying out this procedure on the controller board is required for proper open/short fault and PSTN/POTS telephone line fault detection on the system. In the lower-right of the ...
    • AOR-IP-CSE Revision 1 Call station Configuration

      This article assumes that the suggested default IP scheme for the AOR-IP series is being used. The IP scheme can be found here . This article is for the first version of the AOR-IP-CSE That is based on the PCB with P/N 68820, It has two network ports ...
    • EC-6 Manual Rev 1 1 2024 06 13

      EC-6 Installation & Operation Manual v1.0 1. Getting Started 1.1. Introduction Thank you for your purchase of this EC-6 Telephone Line Consolidator. All Talkaphone equipment is built with an exceptional standard of quality and will provide years of ...