Recommended Programming for Viking K-1900-5

Recommended Programming for Viking K-1900-5

Problem:   ETP series call stations are unable to dial out through an EC-8, EC-2 or AOR on non-traditional analog lines. (Cable modem terminal adapters, fiber module analog terminal adapters, etc.

RESOLUTION:

To program the viking dialer, call into the line connected to the device, and have something answer the call.   This can be an EC-8, AOR, call station, or someone with a handset.
  1. Enter the default access code  *845464 (VIKING),  wait for a double beep in confirmation.
  2. Enter *3 to restrict user dialing,  wait for a double beep in confirmation.
  3. Enter *4 to allow touch tone dialing after the auto dialer has completed it's dialing,  wait for a double beep in confirmation.
  4. Enter *5 to set the delay before dialing to the factory setting,  wait for a double beep in confirmation.
  5. Enter  <phone number to dial>#00,  wait for a double beep in confirmation.
  6. Disconnect the call.
Programming for an EC-8 or AOR
  1. Call into the unit or go off hook on the local phone, and what for three tones.
  2. Enter *31** to access programming,  wait for a single beep in confirmation.
  3. Enter *39*1* to set the unit to mode 1, wait for a single beep in confirmation.
  4. Set the rollover as needed.

Programming for ETP-100, ETP-110, ETP-400 and ETP-500 series devices
  1. Call into the station (*4X* where X is the port number of the station) and wait for the ID tone to complete.
  2. Enter *4** to access programming, wait for a single beep in confirmation.  If two tones are heard repeat the *4**.
  3. Enter *14*3*, to set the unit to mode 3, wait for a single beep in confirmation.
  4. Enter *40*5* to delay the dialing, wait for a single beep in confirmation.   This is the delay before the Talkaphone dials,  The delay may need to be increased to ensure it dials after the Viking unit.
  5. Enter *13*58* as the primary number to be dialed, wait for a single beep in confirmation.
  6. Enter *55* to set the unit to disconnect on 30 seconds of silence from the remote side
  7. Enter *78* to enable two-way conversation on inbound calls.
Misc:
Configure relays as needed and record a greeting if needed.
Pres # to disconnect when completed.

If using Day Night Mode
  • Set the number of rings to at least 5, as the added delay in connecting can make 3 rings very hard to answer.  Enter *18*5*, wait for a single beep in confirmation.
Ideal outcome:
When the call station goes off hook on the telco line the Viking unit should dial and the call should be connected and start to ring.  As the ringing occurs, the Talkaphone unit should dial.  When answered the call station should play its message if configured to do so and reach two way conversation.


If you need additional assistance, please email us at support@talkaphone.com or call 773-539-1100 and select Technical Support.
    • Related Articles

    • Area of Rescue Command Unit Installation Guide for Model AOR-8 and Model AOR-16

      Important Notice THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE ...
    • Programming ETP Series Phones using the local phone on a EC-8 Consolidator

      What is the BASIC programming codes for the analog (ETP) devices by using the local phone on a EC-* Consolidator? Resolution: What you will need: Analog telephone or test-set to dial in access to the ETP device When using an EC-8, connect the local ...
    • Programming the AOR series, and Analog stations for Day/Night Mode

      Programming for an EC-8 or AOR   Call into the unit or go off hook on the local phone, be sure and select the correct bank if working with an AOR-16, AOR-14, or AOR-32, and what for three tones. Enter *31** to access programming,  wait for a single ...
    • Quick programming for the ETP-520 Series call stations

      NOTE: After each programming code, a single beep indicates the code has been accepted. A double-beep indicates an error—re-enter the code again. 1.1. Quick Programming Guide Programming the ETP-520 Series Call Station is relatively quick and easy. ...
    • Troubleshooting AOR Series Trouble Lights

      PURPOSE The purpose of this document is to explain the various reasons for trouble status Lights on the AOR series Command Unit. This includes the AOR-8, AOR-16, AOR-24, and AOR-32. The AOR command units will test the circuit integrity from the main ...