IP Camera
How do I factory reset a VOIP-200 Call Station?
How do I factory reset a VOIP-200 Call Station? Answer: Reset to Factory Default Settings with Static IP 1. While pressing the call button, power up the substation. 2. When the substation LED starts blinking, release the call button after exactly 2 ...
What are the SERIAL settings for the VOIP-500 and VOIP-600 for console connectivity?
What are the SERIAL settings for the VOIP-500 and VOIP-600 for console connectivity? Answer: Using your favorite console/terminal software, configure your serial settings to the following: Speed (baud rate): 115200 Data Bits: 8 Stop bits: 1 Parity: ...
What is the circuit board layout of the Talkaphone VOIP-500/600 Call Station?
What is the circuit board layout of the VOIP-500/600 Call Station? Answer: The layout of the VOIP-500/600 is shown here: If you need additional assistance, please email us at support@talkaphone.com or call 773-539-1100 and select Technical Support.
How do I set the AVM-1 to auto dial a Call Station when I pick up the handset?
How do I set the AVM-1 to auto dial a Call Station when I pick up the handset? Answer: Log into the web interface of the AVM-1 Click the Advanced Settings tab, then click the Call Features menu item in the left hand navigation. About half way down ...
How do I activate the Blue Light (Flash) when the button is pushed? (ETP Analog Devices)
How do I activate the Blue Light (Flash) when the button is pushed? (ETP Analog Devices) Resolution: Assumptions: The ETP-EL (Blue Light) is powered and connected to the BLACK/ORANGE wires from the ETP device which is Output #2. On an ETP device, you ...
How can I protect my Emergency Phone from lightning damage?
How can I protect my Emergency Phone from lightning damage? Answer: All newer outdoor (400/500 Series) Emergency Phones have a green wire. Connect this wire to earth ground. NOTES: We recommend grounding the Tower or other metal enclosure that houses ...
What is the J-Bolt pattern for mounting ETP towers?
What is the J-Bolt pattern for mounting ETP towers? Answer: The pattern is outlined in the image below. (Click to enlarge) Mounting pattern and options for ETP Towers If you need additional assistance, please email us at support@talkaphone.com or ...
What kind of cable do I need to run from the Emergency Phones to my EC-8 Consolidator?
What kind of cable do I need to run from the Emergency Phones to my EC-8 Consolidator? Answer: We strongly recommend twisted, shielded pairs with the shield connected to earth ground only at the EC-8 end. The resistance on the line is not to exceed ...
What is the TELCO OUT port used for on an EC-8?
What is the TELCO OUT port used for on an EC-8? Answer: Another telephone instrument (e.g. fax , modem, standard telephone, etc.) can share the outside phone line with the EC-8 by connecting the outside phone line to the “TELCO IN” port on the EC-8 ...
If I have more than one consolidator can I connect them to the same phone line either in parallel or in series (using a “daisy chain”)?
If I have more than one consolidator can I connect them to the same phone line either in parallel or in series (using a “daisy chain”)? Answer: Each consolidator requires its own phone line or local phone. If you need additional assistance, please ...
How can I have multiple Talkaphone Call Stations use a single TELCO or PBX phone line?
How can I have multiple Talkaphone Call Stations use a single TELCO or PBX phone line? Answer: Each Talkaphone Call Station requires either a dedicated TELCO phone line or analog PBX extension. We currently offer the EC-6 Phone line consolidator. For ...
Does an ETP Call Station remember its programming if I unplug it?
Does an ETP Call Station remember its programming if I unplug it? Answer: Yes. All memory is non-volatile and does not require a back-up battery. If you need additional assistance, please email us at support@talkaphone.com or call 773-539-1100 and ...
I have made several mistakes in programming my ETP Call Station and/or I don't know what has been programmed into my phone. Can I start over from the factory settings?
I have made several mistakes in programming my ETP Call Station and/or I don't know what has been programmed into my phone. Can I start over from the factory settings? Answer: There is no programming code that resets you phone to factory settings. ...
I am using an EC-8 Consolidator in “local” mode. What should I enter as the phone number?
I am using an EC-8 Consolidator in “local” mode. What should I enter as the phone number? Answer: You must enter a phone number (see Primary & Secondary Phone Number Codes, p.6) even though your Talkaphone unit is not using this number to connect to ...
How do I access the VOIP-500/600 using SSH?
How do I access the VOIP-500/600 using SSH? Answer: Set the SSH settings on the VOIP-500/600 Call Station Web GUI application. Ensure you are accessing the Web GUI application of the VOIP-500/600 by navigating to the IP Address set on the device Use ...
What is the SIM Card Size for ETP-GSM (AT&T)
What type of SIM card does the ETP-GSM use for AT&T? ETP-GSM Answer: ETP-GSM uses the STANDARD SIM Card. SIM Card Sizes If you need additional assistance, please email us at support@talkaphone.com or call 773-539-1100 and select Technical Support.
Popular Articles
Programming the AOR series, and Analog stations for Day/Night Mode
Programming for an EC-8 or AOR Call into the unit or go off hook on the local phone, be sure and select the correct bank if working with an AOR-16, AOR-14, or AOR-32, and what for three tones. Enter *31** to access programming, wait for a single ...
BASIC Programming of Analog (ETP) Call Stations
What is the BASIC programming codes for the analog (ETP) devices? Resolution: What you will need: Analog telephone or test-set to dial in access to the ETP device The BASIC of QUICK programming for analog ETP devices is as follows: Default ...
What is the SIM Card Size for ETP-GSM (AT&T)
What type of SIM card does the ETP-GSM use for AT&T? ETP-GSM Answer: ETP-GSM uses the STANDARD SIM Card. SIM Card Sizes If you need additional assistance, please email us at support@talkaphone.com or call 773-539-1100 and select Technical Support.
Front status (CALLING and ANSWERED) LED's on VOIP Call Station Flashing
If the front LED's are continuously flashing on a VOIP-500/600 it means the device cannot register to a SIP server, firmware upgrade is in progress OR the device is in a constant reboot cycle due to not being able to obtain a DHCP IP address. ...
ETP-EL Blue Light flashes when not in a call
Issue: ETP-EL Blue Light flashes when not in a call Environment: ETP Towers that have a Blue Light on/in them. Resolution: Disconnect the ORANGE/BLACK from the call station, if flashing stops, possible issue with the call station. If the flashing ...